Home > Buy Now > Electrical Instruments > Energy Meters > Harmonic Analyzer, Harmonic Meter, Three Phase Meter
 


Shanghai Acrel Ltd.
 
icon Products

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Shanghai Acrel Ltd.
[China]
Address:
No.253 Yulv Road,Madong Industrial Park,Jiading District,Shanghai,China Shanghai Shanghai China
Phone:
86-021-69158338
Contact name:
MICHEL HUA , DIRECTOR OF MARKETING
Inquire now










Shanghai Acrel Ltd.



 
Products

Harmonic Analyzer, Harmonic Meter, Three Phase Meter

Inquire now

Harmonic Analyzer, Harmonic Meter, Three Phase Meter

Click to enlarge image

 Origin China
 Model Number PZ96L-EH
 Brand Name ACREL
 Accuracy Class 0.5
 Dimensions 96*96*85mm
 Display Type Digital Only
 Measuring Energy Range 9999999
 Operating Temperature -20C ~ +55C
 Output Voltage 110V/220V
 Phase Three Phase

1. General
PZ96L-EH harmonic analyzers can measure all the data of all kinds of electrical network. And they have the function of multi rate in multi zone of energy count. At the same time, they can measure more than 31 orders of harmonic. They comply EN 61326:2006 and EN 61010-1:2001.
- Communication and programming via optical interface, or remotely via RS485 output
- Energy: measurement import kWh, kvarh, kva and export kWh and kvarh in class 0.5
- Display of harmonics by order to 31st
- Up to 4DI & 2DO configurable, one DO can be used as Alarm.
- 16 SOEs
- With multi tariff kWh count (4 tariffs & 8 time zones)

2. Technical Feature
- Measurement: VL1, VL2, VL3,VL12, VL23, VL31,AL1, AL2, AL3, ∑AL, F,∑P, P1,P2,P3, ∑Q, Q1,Q2,Q3,∑S, S1,S2,S3,∑PF, PF1,PF2,PF3, MD kW, MD kvar, MD kva, +kWh, +kvarh, kvah, -kWh, -kvarh, 31 harmonics, CF,THFF,KF,UF,UPEAK,UVECTOR,IVECTOR
- Network: 1P2W, 3P3W, 3P4W
- Frequency 45 ~ 65Hz
- Normal: AC 100V, 400V; Overloading: 600V(continuous), 1000V / 30s; Consumption: < 0.2VA
- Current: AC 1A, 5A; Overloading: 6A(continuous), 50A /10s; Consumption: < 0.2VA
- Accuracy Frequency 0.01Hz, reactive energy 1 class, others 0.5 class
- Display: LCD
- Power supply: AC/DC 85~270V; consumption: < 4VA
- Isolation: Power / current input / voltage input: AC2kV/1min;Power / logic inputs / RS485: AC1.5kV/1min;
Inputs / outputs / housing > 5MΩ
- Working T: -20C ~ +55C; Storing T: -30C ~ +70C
- Relative humidity: 5% ~ 95% Non-Condensing;
- Altitude: < 2500m
- Harmonics Individual to 31st order
- Norms:
IEC61000-4-2: 1995 Electrostatic discharge immunity test Level 3
IEC61000-4-3: 1995 Radiated, radio-frequency, Level 3
IEC61000-4-4: 1995 Electrical fast transient pulse immunity test Level
IEC61000-4-5: 1995 Surge immunity test Level 3

3. Options:
- /P: Pulse output Opt coupler pulse output
- /C: Communication RS485 (Modbus-RTU)
- /K: Logic input (DI) 4 drying contact inputs, with +5V power; Logic output (DO) 2 NO contacts (AC 250V/3A, DC 30V/3A)
- /F: Multi tariff kWh count



icon   Price Condition FOB   SHANGHAI
icon   Delivery lead time WITHIN 2 WEEKS
icon   Minimum order 1 Piece/Pieces
icon   Supply ability 10000 Piece/Pieces / Year

Inquire now